Enter your tariff and the watts, hours and thermostat duty cycle of each device to see what your reef tank costs to run per day, month and year, and which equipment uses the most.
Your tariff
Your equipment
Example values: replace them with your own nameplate or, better, measured watts. Leave watts empty to ignore a row.
Optional: energy meter reading
Results
Energy and cost
Where the energy goes
From your meter reading
How the calculator works
- Tariff: enter the unit rate from your own bill and pick a currency symbol (nothing is converted).
- Devices: for each one give watts, hours per day and “% time on”. The pre-filled rows are examples only: replace them with nameplate or, better, measured watts.
- Results update as you type: cost per month and year, kWh per day, month and year, cost per day, a per-device breakdown sorted by energy use, and average continuous power.
- Meter check (optional): enter the kWh a plug-in meter recorded and over how many days to get a daily average and a projected yearly cost.
The science: power, energy and where a reef tank’s electricity goes
Watts are a rate, kilowatt-hours are an amount. Wattage is how fast a device uses energy; your bill charges for the energy used, in kilowatt-hours (kWh). The US Department of Energy’s recipe: wattage × hours per day ÷ 1000 = daily kWh, then × days per year × your rate = annual cost [1]. That is why a modest pump running 24 hours a day can outspend a brighter light.
Duty cycles. The DOE’s example is the refrigerator: always “on”, but actually cycling on and off to hold its temperature [1]. Aquarium heaters and chillers do the same under their thermostats, hence the “% time on” field.
Why heating and cooling can dominate. A tank kept warmer than its room loses heat continuously, and the heater replaces it. Basic physics says conductive heat flow is directly proportional to the surface area and the temperature difference, and inversely proportional to the thickness of the wall [4]. Writing for aquarists, Frank Boldissar notes that heat flow depends on the temperature difference between the water and its surroundings, and that glass loses or gains heat about five times faster than acrylic of the same thickness [7]. Evaporation adds a second, powerful drain: turning water into vapour absorbs a large latent heat, about 2,430 kJ per kilogram at 37 °C [5]. Boldissar puts evaporative cooling at roughly 48 BTU per hour (about 14 W) for each US gallon of top-off water replaced per week [7]. For open water tanks in general, evaporation dominates the heat loss at higher temperatures, and covering the surface avoids a major part of it [6]. A cold room can make the heater the biggest line in the breakdown; a hot one can do the same for a chiller.
Pump heat is not all wasted. The power of submerged pumps and powerheads ends up as heat in the water that the heater would otherwise supply [8]. The calculator still adds every device separately, so treat that overlap as a seasonal bonus, not a discount.
Lighting. A US national-laboratory study found that the link between an LED dimming signal and the power drawn varied widely between drivers, including “dead bands” where power did not change at all [9]. It tested 0–10 V streetlight drivers, not reef fixtures, so the safe lesson is general: measure your light at its real program instead of multiplying maximum watts by the app slider.
Formulas used
- Energy per device (kWh/day) = watts × hours per day × (% time on ÷ 100) ÷ 1000, the DOE formula [1] with a duty-cycle factor.
- Total kWh/day = sum of all devices; kWh/year = kWh/day × 365; kWh/month = kWh/day × 365 ÷ 12 (30.42 days).
- Cost = kWh × your price per kWh (per day, month or year).
- Share of a device = its kWh ÷ total kWh × 100.
- Average continuous power (W) = kWh/day × 1000 ÷ 24.
- Meter reading: kWh/day = measured kWh ÷ days; projected cost per year = kWh/day × 365 × price.
Worked example (the calculator’s default rows, with 0.30 entered as the price per kWh). These are illustrative numbers, not measurements of any particular tank:
| Device | W × h/day × % on | kWh/day |
|---|---|---|
| Lighting | 120 × 10 × 100% | 1.20 |
| Heater | 200 × 24 × 25% | 1.20 |
| Return pump | 40 × 24 × 100% | 0.96 |
| Powerheads | 30 × 24 × 100% | 0.72 |
| Protein skimmer | 25 × 24 × 100% | 0.60 |
| Dosing pump / ATO / controller | 10 × 24 × 100% | 0.24 |
| Total | 4.92 |
4.92 kWh/day × 365 = 1,795.8 kWh/year (shown as 1,796 kWh), or 149.7 kWh per month. At 0.30 per kWh that is 1.48 per day, 44.90 per month and 538.74 per year. The average continuous power is 4,920 Wh ÷ 24 h = 205 W. Lighting and the heater tie at 24.4% each, ahead of the return pump at 19.5%.
Limits of this calculator
- Nameplate watts are a ceiling. The wattage printed on a device is the maximum power it draws; actual use can be lower depending on the setting [1]. Variable-speed pumps and dimmed lights are the usual examples.
- Thermostat duty cycles move with the tank-to-room temperature difference [4][7], so “% time on” shifts with the seasons.
- Dimmed LEDs need measuring, not scaling [9].
- Tariffs are simplified. One flat price per kWh; time-of-use rates and the daily standing charge, paid even with zero use [14], are not modelled.
- Prices change. For orientation only: Eurostat data put the EU average household price for medium consumers (2,500–4,999 kWh a year) at €28.3 per 100 kWh (about €0.28/kWh) including taxes for the first half of 2026, from €11.4 in Hungary to €38.7 in Ireland [10][11]; the EIA’s US average residential price (revenue per kWh sold) was 18.17 cents/kWh in September 2026 [12]; and the price cap for England, Scotland and Wales for 1 October to 31 December 2026 sets an average electricity unit rate of 26.32 p/kWh plus a 54.83 p/day standing charge for Direct Debit; Ofgem notes the government has removed VAT from electricity bills from 1 October 2026 to 31 March 2027 [13]. Always use your own bill.
- Efficiency claims. A retailer guide says DC pumps consume less power than comparable AC pumps but gives no figures [15]; compare measurements, not labels.
How to measure your real consumption
A plug-in energy meter sits between device and socket and shows the energy use or cost of whatever is plugged in [3]; you can usually enter your price per kWh [2]. The DOE notes these monitors are especially useful for devices that do not run constantly [1], and New South Wales advice says fridges need at least 24 hours of monitoring [2]. For a reef tank:
- Measure pumps and skimmers at their normal settings, and lights over a full day of your program.
- Leave the meter on the heater or chiller for several days, in summer and in winter.
- Or meter the whole power strip for a week and enter the kWh in the meter fields above.
- One meter measures one plug; logging several devices at once needs several meters [3].
AVen’s opinion: a meter is the cheapest way to stop guessing. Once you know which line dominates, you know where a lid, an upgrade or a thermostat tweak is worth considering.
Related guides on Reef Life
- What equipment is needed for a saltwater tank
- Reef Tank LED Lighting: How to Measure PAR and Adjust Your Lights
- LED vs T5 reef aquarium lighting
- Review: EcoTech Marine Radion XR30 G6 Blue
- Water flow and the coral boundary layer
- The protein skimmer
- Hands-on with the Aqua Medic Reefdoser EVO 3
- Calcium reactor for the reef aquarium
- Reef Tank Calculator: volume, rock, sand and equipment sizing
References
- U.S. Department of Energy, Energy Saver. “Estimating Appliance and Home Electronic Energy Use.” energy.gov
- NSW Climate and Energy Action. “Discover what’s using the most energy.” energy.nsw.gov.au
- Energy Policy WA. “Monitor your energy use: Common energy-measuring devices for your home” (information sheet, August 2021). wa.gov.au (PDF)
- OpenStax. College Physics 2e, section 14.5 “Conduction.” openstax.org
- OpenStax. College Physics, section 14.3 “Phase Change and Latent Heat.” openstax.org
- The Engineering ToolBox. “Heat Loss from Open Water Tanks.” engineeringtoolbox.com
- Boldissar, F. Aquarium heat transfer, Part 1. Reefs.com. reefs.com
- Aquarium Science. “14.13 Aquarium Electric Cost.” aquariumscience.org
- Waghale, A., Poplawski, M., Pratoomratana, S., Tuenge, J. The Energy and Operational Impacts of Using 0-10V Control for LED Streetlights. Pacific Northwest National Laboratory, PNNL-32949, December 2023. energy.gov (PDF)
- Eurostat. “Electricity prices for household consumers – bi-annual data (from 2007 onwards)” (dataset nrg_pc_204), 2026-S1, all taxes and levies included, band DC. ec.europa.eu
- Euronews. “EU household electricity and gas prices fell in the first half of 2026: Who pays the most?” 12 November 2026 (reporting Eurostat data). euronews.com
- U.S. Energy Information Administration. Electric Power Monthly, “End-use” update (released 24 November 2026, data for September 2026). eia.gov (Table 5.3)
- Ofgem. “Changes to energy price cap between 1 October and 31 December 2026.” ofgem.gov.uk
- Ofgem. “Energy price cap and standing charges explained.” ofgem.gov.uk
- Monte, A. “Should You Use an AC or DC Return Pump For Your Reef Tank?” Bulk Reef Supply (last updated 6 May 2025). bulkreefsupply.com