Salinity too high or too low? Enter your net water volume and your readings in SG or ppt, and this free calculator tells you how much water to swap with RO/DI or fresh saltwater to reach your target.
Your system
Results
Salinity
The swap
Pace (hobby rule of thumb)
How the calculator works
- Enter the net water volume of the whole system: tank plus sump, minus rock, sand and equipment.
- Enter your current and target salinity, either as specific gravity (SG 25/25) or as salinity in ppt. The toggle converts the values you have already typed.
- If salinity is too high, the tool tells you how much tank water to remove and replace with the same volume of RO/DI water.
- If salinity is too low, it tells you how much tank water to replace with freshly mixed saltwater. Enter how salty that new batch is: it must be saltier than your target, or the job cannot be done by water changes alone.
- It also shows both readings in SG and ppt, and a cautious pace for big corrections.
The science: salinity, specific gravity and temperature
Natural seawater typically holds close to 35 grams of dissolved salts per litre, with a usual range of about 33–37 ppt [10]. Randy Holmes-Farley suggests targeting 35 ppt, which corresponds to a specific gravity of 1.0264, and notes that many very successful reef aquaria run anywhere from 32 to 36 ppt [1][3]. He also writes that you will not notice any benefit from changing 34 or 36 ppt to 35 ppt, so small deviations are unlikely to matter [5].
Oceanographers measure salinity in two main ways. Practical salinity (the 1978 scale, PSS-78) is defined from the electrical conductivity of a sample compared with a standard potassium chloride solution, and it has no units [8]. Absolute salinity is the mass of dissolved material per kilogram of seawater, in g/kg; for standard seawater it is about 35.16504/35 times the practical salinity, so a practical salinity of 35 is roughly 35.165 g/kg [8]. In the hobby both are casually called “ppt”. This calculator works with practical salinity, which is what the international equation of state uses.
Specific gravity is the density of your water divided by the density of pure water, and the answer depends on the temperatures of both [2]. The same S = 35 seawater reads 1.0269 on the 60 °F standard and 1.0264 on the 77 °F (25 °C) standard [2]. 77 °F (25 °C) is a popular standard for hobby hydrometers, 60 °F (15.6 °C) is common for scientific hydrometers, and some hobby hydrometers do not say which standard they use [2]. This tool uses SG 25/25: both the sample and the pure water reference at 25 °C.
Refractometers need a proper standard. Zeroing with RO/DI water only fixes an offset; it cannot catch a “slope” error, where the instrument reads correctly at zero but wrongly near seawater strength [3]. Holmes-Farley recommends checking any salinity device against a seawater standard at least once [3]. A home-made option for refractometers is 3.65 g of sodium chloride dissolved in 96.35 g of purified water [4].
Formulas used
SG and ppt. Densities come from the one-atmosphere international equation of state of seawater, EOS-80 (Millero & Poisson, 1981), using the algorithm and check values published by UNESCO [6][7]. At 25 °C it gives 997.05 kg/m³ for pure water and 1023.34 kg/m³ for S = 35, so SG(25/25) = 1.0264. Turning an SG back into ppt is done numerically (bisection), and the round trip agrees to better than 0.01 ppt. EOS-80 was the standard for about 30 years [9]; in 2009 the IOC adopted TEOS-10 as its successor [8], but for converting aquarium readings the difference is far below what hobby instruments can resolve.
Water to swap. The tool balances the salt. You remove a volume Vr of tank water (salinity Snow) and add the same volume of water at salinity Sadd (0 for RO/DI). In its simplest form, treating one litre as one kilogram:
- Too high: Vr = V × (Snow − Starget) / Snow
- Too low: Vr = V × (Starget − Snow) / (Sadd − Snow)
Seawater is denser than fresh water, so the headline result goes one step further. It weights each volume by its EOS-80 density ρ at 25 °C: Vr = V × ρnow × (Snow − Starget) / [ρnow × (Snow − Starget) + ρadd × (Starget − Sadd)]. Volumes are assumed to add up when mixed.
Worked example (values entered in ppt). A 200 L system reads 37 ppt (SG 1.0279), and you want 35 ppt (SG 1.0264). The simple formula gives 200 × 2 / 37 = 10.8 L. The density-weighted version gives 11.1 L, about 5.5 % of the system, replaced with RO/DI water. Now take the opposite case: 200 L at 33 ppt (SG 1.0249). Raising it to 35 ppt with a new batch at 36 ppt means swapping 133.2 L, two thirds of the system. With a batch at 38 ppt, the swap drops to 79.8 L. That is why the tool asks how salty your new saltwater is. If you type the rounded SG values instead, the results shift slightly (for example 11.0 L instead of 11.1 L, and 136 L instead of 133 L), because each 0.0001 of SG is about 0.13 ppt.
Pace. Bulk Reef Supply, an aquarium retailer, gives as a general rule no more than 2 ppt of change per day, to reduce the chances of osmotic shock [11]. The article cites no study, and no peer-reviewed limit for reef tanks turned up while researching this tool, so treat it as a rule of thumb. My own opinion (AVen) is that slower is kinder whenever nothing forces your hand. For comparison, Jay Hemdal advises returning fish to full salinity after hyposalinity treatment slowly, over five to seven days [12]; that guidance is for fish in a treatment system, not for a reef tank with corals and invertebrates.
Limits of this calculator
- Net volume. Every result scales with your volume estimate. If that estimate is 10 % off, so is the swap. Measure it if you can, or use the Reef Tank Calculator.
- Measurement error is usually bigger than the math error. Calibrated with pure water only, many inexpensive refractometers read a 35 ppt standard about 1 ppt off, but some read much further off [3]. In one of Holmes-Farley’s illustrative examples, a simple offset calibration error makes 35 ppt seawater read about 31 ppt [3]. A tested swing-arm hydrometer read S = 32 in an S = 35 solution [2]. Small glass hydrometers are precise to about 0.001–0.0005 SG [12].
- Temperature. For floating hydrometers calibrated at 15 °C (60 °F), correction tables are available; for other calibration temperatures Holmes-Farley suggests adding about 0.00035 for every °C the water is above the calibration temperature, and subtracting it when below [2]. Use the correction your instrument’s maker gives, or use automatic temperature compensation (ATC) where you have it; ATC is a linear correction to an effect that may not be linear [3].
- Evaporation and top-off. Evaporation removes water, not salt. If salinity keeps creeping up, check that you top off with RO/DI water only [5].
- No grams of dry salt. The tool does not convert a salinity change into grams of dry salt mix, because no reliable source for that conversion across brands was found. Dissolve the mix in water as its maker directs, measure the batch, and enter that reading.
- Above 42 ppt practical salinity is used outside the range for which it is defined (2–42), so the conversions there are less certain [8][9].
Related guides on Reef Life
- Why salinity matters in a reef aquarium: evaporation and freshwater top-off
- Maintaining a reef aquarium: the importance of water changes
- Essential water parameters in a reef aquarium
- Reef Tank Calculator – work out your net water volume
- Marine fish quarantine protocol – if you are adjusting salinity for a quarantine system
References
- Holmes-Farley, R. (2004). Reef Aquarium Water Parameters. Reefkeeping Magazine, May 2004. reefkeeping.com/issues/2004-05/rhf/
- Holmes-Farley, R. (2004). Temperature Corrections for Hydrometers. Reefkeeping Magazine, July 2004. reefkeeping.com/issues/2004-07/rhf/
- Holmes-Farley, R. (2006). Refractometers and Salinity Measurement. Reefkeeping Magazine, December 2006. reefkeeping.com/issues/2006-12/rhf/
- Holmes-Farley, R. (2004). Reef Aquarium Salinity: Homemade Calibration Standards. Reefkeeping Magazine, June 2004. reefkeeping.com/issues/2004-06/rhf/
- Holmes-Farley, R. (2007). The “How To” Guide to Reef Aquarium Chemistry for Beginners, Part 1: The Salt Water Itself. Reefkeeping Magazine, March 2007. reefkeeping.com/issues/2007-03/rhf/
- Millero, F. J. & Poisson, A. (1981). International one-atmosphere equation of state of seawater. Deep-Sea Research Part A, 28(6), 625–629. doi:10.1016/0198-0149(81)90122-9
- Fofonoff, N. P. & Millard, R. C. Jr. (1983). Algorithms for computation of fundamental properties of seawater. UNESCO Technical Papers in Marine Science 44. darchive.mblwhoilibrary.org/handle/1912/2470
- IOC, SCOR & IAPSO (2010). The international thermodynamic equation of seawater – 2010 (TEOS-10). Intergovernmental Oceanographic Commission, Manuals and Guides No. 56, UNESCO. teos-10.org/pubs/TEOS-10_Manual.pdf
- Millero, F. J. (2010). History of the equation of state of seawater. Oceanography, 23(3), 18–33. doi:10.5670/oceanog.2010.21
- NOAA National Weather Service, JetStream. Sea Water. noaa.gov/jetstream/ocean/sea-water
- Farnsworth, R. (updated 2025). Managing Salinity Swings in a Saltwater Aquarium. Bulk Reef Supply. bulkreefsupply.com
- Hemdal, J. Salinity Measurements for Marine Aquariums. Tropical Fish Hobbyist Magazine. tfhmagazine.com
